Untitled Document

StreamPro Software

The StreamPro mobile software contains mid-section discharge measurement data collection capabilities for the StreamPro using windows Mobile devices. The table below is for the mid-section portion of the StreamPro mobile software.A license is required with each instrument used for data collection of mid-section measurements.

Version
Status
Changes and Known Issues
Recommended
-verified Windows Mobile 6 compatibility
-*requires StreamPro firmware 31.07 or later
-fixed Good Bins indicator
3.33
Do Not Use
-added support for StreamPro Compass
-added support for 6m long range mode
-fixed side lobe calulation to match WinRiver II
-*requires firmware 31.07 or later.
-changed license method
3.32
Testing
-updated language pack
-known issue: calculates side lobe differently than WinRiver II, resulting in different Q when reprocessed
3.31
Testing
-added support for some Windows Mobile 5 devices
-fixed problem with temperature in english units
-Improved algorithm to match WinRiver II calculations.
-known issue: calculates side lobe differently than WinRiver II, resulting in different Q when reprocessed
3.20
Testing
-last supported release for PocketPC's running Windows Mobile 2003
-known issue: numerous bugs with SxS
-known issue: problem including edge discharge during data acquisition
-known issue: calculates side lobe differently than WinRiver II, resulting in different Q when reprocessed
-this version should only be used on PDAs that are not compatible with newer versions. OSW recommends upgrading to a newer PDA compatible with the latest version of software

Software/Firmware Status Definitions

Required Minimum: Minimum version required. This version has proven stable and may contain enhancements that are significant over previous required versions

Recommended: Shown to have been reliable and contains features that result in a recommended upgrade over the required version. There could be a few specific use cases where this version may have issues that would result in some users not using this version. If so, those cases will be noted.

Allowed*: Deemed reliable during initial testing. Any issues will be noted along with improvements available over prior versions. Use of allowed versions may be desired in cases when the changes benefit a significant number of the user's conditions or equipment. For example: a new version of software is released that adds support for new hardware. If the user has this hardware, they would need to upgrade to the newer software before it becomes recommended or required. Use of these versions by experienced users will also help OSW identify any unknown issues.

Testing*: OSW is currently testing; any known issues or advantages over prior release will be noted. The use of a version that is in testing should usually be limited to advanced users that can trouble shoot potential issues and provide feedback on any irregularities or problems observed.

Do Not Use: A version either prior to the required minimum or that contains issues that significantly affect operations.

*Note: A version may remain in Allowed or Testing indefinitely. Example: A new version is released while the prior version is still in Testing. In this case the prior version may remain in Testing, while future testing efforts are placed on the newer version.


Return to Mid-Section Measurements - Software and Firmware


Links to the manufacturer's software and firmware are provided primarily as a service for USGS users. However, in some cases, access has also been provided for other agencies with the manufacturer's permission. Software or firmware without a direct download link should be obtained from the manufacturer.